BUILDING SPECS

Year Built1997, renovated 2016
Size170,519 sq. ft.
FloorsOne-story
LayoutThe building is configured in a central core design
Column Spacing24’ x 24’
StructuralReinforced steel frame with concrete footings and foundations
Exterior FaçadeDryvit exterior designed with a series of setbacks and reveals, and a reflective window system
RoofNew rubber EDPM roof overlay completed in 2002
Ceiling Heights9’+ finished ceilings; 13’ slab-to-slab
HVACThe building utilizes a VAV distribution system consisting of 11 Aaon cooking only rooftop units and hot water circulating pumps with reheat coils and gas fired boilers for heat. Upgraded HVAC in the Accenture space. Programmable systems control the building’s HVAC, lighting and electric. Five roof top units are dedicated to the labs. Provides 3 split systems for the data center, and Accenture has 8 split systems for their data centers and training rooms.
ElectricalSwitchgear is 3200 amp double ended unit Square D. Transformer is 2666 KVA and is 277/480 volt, 3 Phase. Substation on-site. Baxter has its own emergency generator
PlumbingDomestic hot water is provided by two 100-gallon capacity Ameriglas gas-fired hot water heaters.
Security24-hour monitored card access
Fire ProtectionWet sprinkler system
Common Area Finishes:Lobby has granite/marble, wood veneer and vinyl walls and indirect and spot lighting. Common areas have vinyl wall covering about 5/8-inch gypsum board and carpeted floors
Loading DockOne loading dock is located in the back of the building
AccessIngress/egress is provided via two driveways on Spring Street
Total Parking670 surface parking spaces (3.93/1,000 square feet). Parking is located predominantly on the southern and western portions of the Property.

41 Spring Street